BITZER Electronics ServiceTool
BITZER Electronics ServiceTool
Version History
Update Comparison
App Status
  • Earliest Version Launch Date Globally
    07/16/2020
  • Latest Version
    2.18.26662
  • Time Since Latest Version
    100days2Hour
  • Total Updated Versions (last 1 year)
    4

Version Timeline

Hover over "Icon" to view updates. Click "Icon" to view comparison
Version History
Display Content
Date
  • -
2024 years
4 month
18
19
20
21
22
23
24
25
26
27
28
29
30
5 month
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
6 month
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
7 month
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

Version History

  • Version2.18.26662
    04/09/2024
    Size:185.83M

    BITZER Electronics ServiceTool

    Update Log

    CM-RC-02: Reconfiguration of the operating mode from "Protection mode (SE-B)" into "Compressor operation mode" optimized.

    Screenshots
    App Description

    This is the App edition of the BEST SOFTWARE (BITZER Electronics Service Tool) for connecting to BITZER IQ products that support Bluetooth. Quickly configure the devices, monitor the operation and view the alarms including alarm help texts. Furthermore, the datalogs can be retrieved from the devices, visualized and uploaded to the myBITZERcloud for storage and sharing with other devices and people.
    Supported products:
    // IQ MODULE CM-RC-02
    - For firmware update use the Windows version of BEST
    // IQ MODULE CM-RC-01
    - Requires firmware version 2.5.246.00 or newer
    - For firmware update use the Windows version of BEST as it requires to connect via the BEST converter
    // IQ MODULE CM-SW-01
    - Requires firmware version 2.8.82.00 or newer
    - For firmware update use the Windows version of BEST as it requires to connect via the BEST converter
    // CSV
    - Bluetooth is available by the CSV frequency inverters with the control board of the 2nd generation. This control board can be recognized by the STO input (orange connector) or the RJ12 socket for the BEST converter
    - Requires firmware version 1.92 or newer
    - For first configuration (change of refrigerant or configuring the compressor type in case of spare parts) use the Windows version of BEST as it requires to connect via the BEST converter. Also for firmware updates
    // ECOSTAR LHV5E and LHV7E
    - Requires firmware version 5.0.2.0 or newer
    - For firmware update use the Windows version of BEST

  • Version2.18.25759
    01/24/2024
    Size:185.72M

    BITZER Electronics ServiceTool

    Update Log

    - The Operational Graph now supports vertical and horizontal orientation.
    - Compressor selection wizard added.
    - BEST files can be imported.
    - Alarms
    - Alarm reset types get shown.
    - CSV: Fault log added.
    - BDN registration
    - Already existing Sites/Sub-Sites and Systems can be selected when being logged into myBITZER.
    - Proper failure messages gets shown instead of codes.
    - IQ MODULE CM-RC-02 integrated
    - Product data updated. For details, see http://best.bitzer.tech
    - Bugfixes for iPad

    Screenshots
    App Description

    This is the App edition of the BEST SOFTWARE (BITZER Electronics Service Tool) for connecting to BITZER IQ products that support Bluetooth. Quickly configure the devices, monitor the operation and view the alarms including alarm help texts. Furthermore, the datalogs can be retrieved from the devices, visualized and uploaded to the myBITZERcloud for storage and sharing with other devices and people.
    Supported products:
    // IQ MODULE CM-RC-02
    - For firmware update use the Windows version of BEST
    // IQ MODULE CM-RC-01
    - Requires firmware version 2.5.246.00 or newer
    - For firmware update use the Windows version of BEST as it requires to connect via the BEST converter
    // IQ MODULE CM-SW-01
    - Requires firmware version 2.8.82.00 or newer
    - For firmware update use the Windows version of BEST as it requires to connect via the BEST converter
    // CSV
    - Bluetooth is available by the CSV frequency inverters with the control board of the 2nd generation. This control board can be recognized by the STO input (orange connector) or the RJ12 socket for the BEST converter
    - Requires firmware version 1.92 or newer
    - For first configuration (change of refrigerant or configuring the compressor type in case of spare parts) use the Windows version of BEST as it requires to connect via the BEST converter. Also for firmware updates
    // ECOSTAR LHV5E and LHV7E
    - Requires firmware version 5.0.2.0 or newer
    - For firmware update use the Windows version of BEST

  • Version2.18.25671
    01/18/2024
    Size:185.72M

    BITZER Electronics ServiceTool

    Update Log

    - The Operational Graph now supports vertical and horizontal orientation.
    - Compressor selection wizard added.
    - BEST files can be imported.
    - Alarms
    - Alarm reset types get shown.
    - CSV: Fault log added.
    - BDN registration
    - Already existing Sites/Sub-Sites and Systems can be selected when being logged into myBITZER.
    - Proper failure messages gets shown instead of codes.
    - IQ MODULE CM-RC-02 integrated
    - Product data updated. For details, see http://best.bitzer.tech

    Screenshots
    App Description

    This is the App edition of the BEST SOFTWARE (BITZER Electronics Service Tool) for connecting to BITZER IQ products that support Bluetooth. Quickly configure the devices, monitor the operation and view the alarms including alarm help texts. Furthermore, the datalogs can be retrieved from the devices, visualized and uploaded to the myBITZERcloud for storage and sharing with other devices and people.
    Supported products:
    // IQ MODULE CM-RC-02
    - For firmware update use the Windows version of BEST
    // IQ MODULE CM-RC-01
    - Requires firmware version 2.5.246.00 or newer
    - For firmware update use the Windows version of BEST as it requires to connect via the BEST converter
    // IQ MODULE CM-SW-01
    - Requires firmware version 2.8.82.00 or newer
    - For firmware update use the Windows version of BEST as it requires to connect via the BEST converter
    // CSV
    - Bluetooth is available by the CSV frequency inverters with the control board of the 2nd generation. This control board can be recognized by the STO input (orange connector) or the RJ12 socket for the BEST converter
    - Requires firmware version 1.92 or newer
    - For first configuration (change of refrigerant or configuring the compressor type in case of spare parts) use the Windows version of BEST as it requires to connect via the BEST converter. Also for firmware updates
    // ECOSTAR LHV5E and LHV7E
    - Requires firmware version 5.0.2.0 or newer
    - For firmware update use the Windows version of BEST

  • Version2.18.25461
    01/12/2024
    Size:185.72M

    BITZER Electronics ServiceTool

    Update Log

    - The Operational Graph now supports vertical and horizontal orientation.
    - Compressor selection wizard added.
    - BEST files can be imported.
    - Alarms
    - Alarm reset types get shown.
    - CSV: Fault log added.
    - BDN registration
    - Already existing Sites/Sub-Sites and Systems can be selected when being logged into myBITZER.
    - Proper failure messages gets shown instead of codes.
    - IQ MODULE CM-RC-02 integrated
    - Product data updated. For details, see http://best.bitzer.tech

    Screenshots
    App Description

    This is the App edition of the BEST SOFTWARE (BITZER Electronics Service Tool) for connecting to BITZER IQ products that support Bluetooth. Quickly configure the devices, monitor the operation and view the alarms including alarm help texts. Furthermore, the datalogs can be retrieved from the devices, visualized and uploaded to the myBITZERcloud for storage and sharing with other devices and people.
    Supported products:
    // IQ MODULE CM-RC-01
    - Requires firmware version 2.5.246.00 or newer
    - For firmware update use the Windows version of BEST as it requires to connect via the BEST converter
    // IQ MODULE CM-SW-01
    - Requires firmware version 2.8.82.00 or newer
    - For firmware update use the Windows version of BEST as it requires to connect via the BEST converter
    // CSV
    - Bluetooth is available by the CSV frequency inverters with the control board of the 2nd generation. This control board can be recognized by the STO input (orange connector) or the RJ12 socket for the BEST converter
    - Requires firmware version 1.92 or newer
    - For first configuration (change of refrigerant or configuring the compressor type in case of spare parts) use the Windows version of BEST as it requires to connect via the BEST converter. Also for firmware updates
    // ECOSTAR LHV5E and LHV7E
    - Requires firmware version 5.0.2.0 or newer
    - For firmware update use the Windows version of BEST

  • Version2.17.22770
    02/10/2023
    Size:198.28M

    BITZER Electronics ServiceTool

    Update Log

    IQ MODULE CM-RC-01:
    - Firmware version 2.23.287.00 integrated
    - 8-cylinder CO₂ compressors 8FTE-100, 8FTE-140 and 8CTE-140 added
    - ECOLINE 2 cylinder compressors 2KES-05 .. 2CES-4 and 2EESH-2 .. 2CESH-4 made available as standard
    IQ MODULE CM-SW-01:
    - Compressor HSK9593-300 as successor for the compressor HSK9593-280 added
    - The phase monitoring can be activated by the motor starter functions “Direct on Line (DOL)“, “Part Winding(PW)” and “Star Delta”
    Various bugfixes

    Screenshots
    App Description

    This is the App edition of the BEST SOFTWARE (BITZER Electronics Service Tool) for connecting to BITZER IQ products that support Bluetooth. Quickly configure the devices, monitor the operation and view the alarms including alarm help texts. Furthermore, the datalogs can be retrieved from the devices, visualized and uploaded to the myBITZERcloud for storage and sharing with other devices and people.
    Supported products:
    // IQ MODULE CM-RC-01
    - Requires firmware version 2.5.246.00 or newer
    - For firmware update use the Windows version of BEST as it requires to connect via the BEST converter
    // IQ MODULE CM-SW-01
    - Requires firmware version 2.8.82.00 or newer
    - For firmware update use the Windows version of BEST as it requires to connect via the BEST converter
    // CSV
    - Bluetooth is available by the CSV frequency inverters with the control board of the 2nd generation. This control board can be recognized by the STO input (orange connector) or the RJ12 socket for the BEST converter
    - Requires firmware version 1.92 or newer
    - For first configuration (change of refrigerant or configuring the compressor type in case of spare parts) use the Windows version of BEST as it requires to connect via the BEST converter. Also for firmware updates
    // ECOSTAR LHV5E and LHV7E
    - Requires firmware version 5.0.2.0 or newer
    - For firmware update use the Windows version of BEST

  • Version2.16.20717
    07/21/2022
    Size:186.37M

    BITZER Electronics ServiceTool

    Update Log

    - Livelog feature added:
    - Whenever BEST is connected to a product, it logs automatically all operating data and parameters in the highest possible resolution
    - The operation can be visualized in a graph like known from the Windows version
    - The BEST file can be saved by a button at any time
    - Product data updated in correspondence with BEST 2.16 for Windows. For more details about the newly supported compressors, refrigerants and firmware see http://best.bitzer.tech

    Screenshots
    App Description

    This is the App edition of the BEST SOFTWARE (BITZER Electronics Service Tool) for connecting to BITZER IQ products that support Bluetooth. Quickly configure the devices, monitor the operation and view the alarms including alarm help texts. Furthermore, the datalogs can be retrieved from the devices, visualized and uploaded to the myBITZERcloud for storage and sharing with other devices and people.
    Supported products:
    // IQ MODULE CM-RC-01
    - Requires firmware version 2.5.246.00 or newer
    - For firmware update use the Windows version of BEST as it requires to connect via the BEST converter
    // IQ MODULE CM-SW-01
    - Requires firmware version 2.8.82.00 or newer
    - For firmware update use the Windows version of BEST as it requires to connect via the BEST converter
    // CSV
    - Bluetooth is available by the CSV frequency inverters with the control board of the 2nd generation. This control board can be recognized by the STO input (orange connector) or the RJ12 socket for the BEST converter
    - Requires firmware version 1.92 or newer
    - For first configuration (change of refrigerant or configuring the compressor type in case of spare parts) use the Windows version of BEST as it requires to connect via the BEST converter. Also for firmware updates
    // ECOSTAR LHV5E and LHV7E
    - Requires firmware version 5.0.2.0 or newer
    - For firmware update use the Windows version of BEST

  • Version2.16.20710
    07/19/2022
    Size:176.57M

    BITZER Electronics ServiceTool

    Update Log

    - Livelog feature added:
    - Whenever BEST is connected to a product, it logs automatically all operating data and parameters in the highest possible resolution
    - The operation can be visualized in a graph like known from the Windows version
    - The BEST file can be saved by a button at any time
    - Product data updated in correspondence with BEST 2.16 for Windows. For more details about the newly supported compressors, refrigerants and firmware see http://best.bitzer.tech

    Screenshots
    App Description

    This is the App edition of the BEST SOFTWARE (BITZER Electronics Service Tool) for connecting to BITZER IQ products that support Bluetooth. Quickly configure the devices, monitor the operation and view the alarms including alarm help texts. Furthermore, the datalogs can be retrieved from the devices, visualized and uploaded to the myBITZERcloud for storage and sharing with other devices and people.
    Supported products:
    // IQ MODULE CM-RC-01
    - Requires firmware version 2.5.246.00 or newer
    - For firmware update use the Windows version of BEST as it requires to connect via the BEST converter
    // IQ MODULE CM-SW-01
    - Requires firmware version 2.8.82.00 or newer
    - For firmware update use the Windows version of BEST as it requires to connect via the BEST converter
    // CSV
    - Bluetooth is available by the CSV frequency inverters with the control board of the 2nd generation. This control board can be recognized by the STO input (orange connector) or the RJ12 socket for the BEST converter
    - Requires firmware version 1.92 or newer
    - For first configuration (change of refrigerant or configuring the compressor type in case of spare parts) use the Windows version of BEST as it requires to connect via the BEST converter. Also for firmware updates
    // ECOSTAR LHV5E and LHV7E
    - Requires firmware version 5.0.2.0 or newer
    - For firmware update use the Windows version of BEST

  • Version2.14.14882
    07/13/2021
    Size:246.13M

    BITZER Electronics ServiceTool

    Update Log

    Bug fix: ECOSTAR: For several parameters it was unnecessarily required, to set the ECOSTAR operating mode to Off, before parameter changes could be transferred

    Screenshots
    App Description

    This is the App edition of the BEST SOFTWARE (BITZER Electronics Service Tool) for connecting to BITZER IQ products that support Bluetooth. Quickly configure the devices, monitor the operation and view the alarms including alarm help texts. Furthermore, the datalogs can be retrieved from the devices, visualized and uploaded to the myBITZERcloud for storage and sharing with other devices and people.
    Supported products:
    // IQ MODULE CM-RC-01
    - Requires firmware version 2.5.246.00 or newer
    - For firmware update use the Windows version of BEST as it requires to connect via the BEST converter
    // IQ MODULE CM-SW-01
    - Requires firmware version 2.8.82.00 or newer
    - For firmware update use the Windows version of BEST as it requires to connect via the BEST converter
    // CSV
    - Bluetooth is available by the CSV frequency inverters with the control board of the 2nd generation. This control board can be recognized by the STO input (orange connector) or the RJ12 socket for the BEST converter
    - Requires firmware version 1.92 or newer
    - For first configuration (change of refrigerant or configuring the compressor type in case of spare parts) use the Windows version of BEST as it requires to connect via the BEST converter. Also for firmware updates
    // ECOSTAR LHV5E and LHV7E
    - Requires firmware version 5.0.2.0 or newer
    - For firmware update use the Windows version of BEST

  • Version2.14.0
    06/23/2021
    Size:246.12M

    BITZER Electronics ServiceTool

    Update Log

    - New language: Spanish
    - Bug fix: The compressor doesn´t stop anymore when providing an alarm reset command while the compressor is running
    - Product data updated in correspondence with BEST 2.14 for Windows. For details about the newly supported compressors, refrigerants and firmware see http://best.bitzer.tech

    Screenshots
    App Description

    This is the App edition of the BEST SOFTWARE (BITZER Electronics Service Tool) for connecting to BITZER IQ products that support Bluetooth. Quickly configure the devices, monitor the operation and view the alarms including alarm help texts. Furthermore, the datalogs can be retrieved from the devices, visualized and uploaded to the myBITZERcloud for storage and sharing with other devices and people.
    Supported products:
    // IQ MODULE CM-RC-01
    - Requires firmware version 2.5.246.00 or newer
    - For firmware update use the Windows version of BEST as it requires to connect via the BEST converter
    // IQ MODULE CM-SW-01
    - Requires firmware version 2.8.82.00 or newer
    - For firmware update use the Windows version of BEST as it requires to connect via the BEST converter
    // CSV
    - Bluetooth is available by the CSV frequency inverters with the control board of the 2nd generation. This control board can be recognized by the STO input (orange connector) or the RJ12 socket for the BEST converter
    - Requires firmware version 1.92 or newer
    - For first configuration (change of refrigerant or configuring the compressor type in case of spare parts) use the Windows version of BEST as it requires to connect via the BEST converter. Also for firmware updates
    // ECOSTAR LHV5E and LHV7E
    - Requires firmware version 5.0.2.0 or newer
    - For firmware update use the Windows version of BEST

  • Version2.13.12702
    01/27/2021
    Size:230.18M

    BITZER Electronics ServiceTool

    Update Log

    Bugfix: Correction of compressor serial number dependent parameter handling of CM-SW-01 with compressors produced from January 2021

    Screenshots
    App Description

    This is the App edition of the BEST SOFTWARE (BITZER Electronics Service Tool) for connecting to BITZER IQ products that support Bluetooth. Quickly configure the devices, monitor the operation and view the alarms including alarm help texts. Furthermore, the datalogs can be retrieved from the devices, visualized and uploaded to the myBITZERcloud for storage and sharing with other devices and people.
    Supported products:
    // IQ MODULE CM-RC-01
    - Requires firmware version 2.5.246.00 or newer
    - For firmware update use the Windows version of BEST as it requires to connect via the BEST converter
    // IQ MODULE CM-SW-01
    - Requires firmware version 2.8.82.00 or newer
    - For firmware update use the Windows version of BEST as it requires to connect via the BEST converter
    // CSV
    - Bluetooth is available by the CSV frequency inverters with the control board of the 2nd generation. This control board can be recognized by the STO input (orange connector) or the RJ12 socket for the BEST converter
    - Requires firmware version 1.92 or newer
    - For first configuration (change of refrigerant or configuring the compressor type in case of spare parts) use the Windows version of BEST as it requires to connect via the BEST converter. Also for firmware updates
    // ECOSTAR LHV5E and LHV7E
    - Requires firmware version 5.0.2.0 or newer
    - For firmware update use the Windows version of BEST

    • 1
    • 2